Maricopa Community Colleges  DMI292   20036-20075 
Official Course Description: MCCCD Approval: 06/17/03
DMI292 20036-20075 LAB 1 Credit(s) 3 Period(s)
Nuclear Medicine Image Evaluation V
Emphasis on positron emission tomography (PET) therapy imaging and other studies new to the nuclear medicine imaging field. Evaluation of images related to clinical situations and procedures including patient history, patient preparation, name and energy of radiopharmaceutical, method of localization, dosimetry, and method of clearance. Normal and abnormal distribution. Need for additional views and/or procedures. Technical limitations, protocol and equipment parameters and procedure results.
Prerequisites: DMI290. Corequisites: DMI278 or permission of Nuclear Medicine Technology program director.
Go to Competencies    Go to Outline
 
MCCCD Official Course Competencies:
 
DMI292   20036-20075 Nuclear Medicine Image Evaluation V
1. Explain the patient history and patient preparation for PET therapy imaging and other new, nuclear medicine imaging procedures. (I)
2. Select the appropriate radiopharmaceutical for PET therapy imaging and other new, nuclear medicine imaging procedures. (II)
3. State the name, energy, and method of localization, dosimetry, and method of clearance of an identified radiopharmaceutical for a selected procedure. (II)
4. Describe the images of a selected procedure to include normal distribution, abnormal distribution, artifacts, additional views, additional procedures, any technical limitations either patient or equipment. (III)
5. Identify technical limitations and corrective actions. (IV)
6. Explain the imaging protocol for a selected procedure to include indications, contraindications, and imaging procedure. (IV)
7. Set equipment parameters for equipment used. (V)
Go to Description    Go to top of Competencies
 
MCCCD Official Course Outline:
 
DMI292   20036-20075 Nuclear Medicine Image Evaluation V
    I. Patient
        A. History
        B. Preparation
      II. Radiopharmaceutical
          A. Name
          B. Energy
          C. Method of localization
          D. Dosimetry
          E. Method of clearance
        III. Procedure images
            A. Normal distribution
            B. Abnormal distribution
            C. Artifacts
            D. Additional views
            E. Additional procedures
            F. Technical limitations
              1. Patient
              2. Equipment
          IV. Procedure protocol
              A. Indications
              B. Contraindications
              C. Imaging procedure
            V. Equipment parameters
                A. Camera
                B. Collimator
                C. Computer set-up
            Go to Description    Go to top of Competencies    Go to top of Outline